Modelling of Edge Insulation Depending on Boundary Conditions for the Ground Level
Abstract
The article presents results of CFD software aided simulations of a thermal bridge, existing at the wall-slab on ground connection. Calculations were made for different variants of the edge insulation location. Schemes without any edge insulation, with some vertical insulation, horizontal, diagonal, and diagonal combined with insulation used as formwork under the slab on ground were analysed. Each variant was differentiated with boundary conditions for the ground. Vertical borders of the model in the ground, as well as the lower border were described in the first solution as adiabatic, while in the second case, a variable temperature value, depending on the ground depth, was set. For comparison, additional calculations were conducted for non-stationary conditions, in which the initial temperature of the ground was set to the average annual temperature of air. The calculations were based on the location of Szczecin, for which the outside air temperature was set to -16.0°C. Results obtained from the simulation were then used to determine the thermal bridge parameters, in particular, thermal coupling coefficient and linear thermal transmittance. The effect of the set of boundary conditions is clearly seen. In general, for all the five variants, lower values of heat fluxes and linear thermal transmittances were obtained, when variable temperature in the ground was assumed. From the point of view of energy balance, it is more favourable to use the values of ψg obtained when the ground temperature is taken into account. The data breakdown shows that application of the actual temperature distribution in the ground to a model has a strong effect on distribution of the 0.0°C isotherm. The adiabatic model indicates that the ground under the slab freezes, while the model, which takes into account the temperature of the ground, shows that the ground under the floor has positive temperatures and the 0.0°C isotherm reaches only the edge of the outer wall. Moreover, the effect of the adopted ground temperatures on the hygrothermal parameters of the cases in question was demonstrated. The models that take into account the temperature of the ground result in more favourable values than those in the adiabatic models. For non-stationary heat flow conditions, the advantages of the diagonal edge isolation, which caused significant offset of the zero isotherm from the foundations, were presented. Variants of horizontal and diagonal edge insulations eliminate the risk of freezing of the foundation and the ground beneath it.
- Publication:
-
Materials Science and Engineering Conference Series
- Pub Date:
- October 2017
- DOI:
- 10.1088/1757-899X/245/4/042003
- Bibcode:
- 2017MS&E..245d2003S