Microstructure Evolution During Stainless Steel-Copper Vacuum Brazing with a Ag/Cu/Pd Filler Alloy: Effect of Nickel Plating
Abstract
Vacuum brazing of stainless steel and copper plates was done using a silver-based filler alloy. In one set of experiments, around 30-µm-thick nickel coatings were electrochemically applied on stainless steel plates before carrying out the brazing runs and its effect in making changes in the braze-zone microstructure was studied. For brazing temperature of 830 °C, scanning electron microscopy examination of the braze-zone revealed that relatively sound joints were obtained when brazing was done with nickel-coated stainless steel than with uncoated one. However, when brazing of nickel-coated stainless steel and copper plates was done at 860 °C, a wide crack appeared in the braze-zone adjacent to copper side. Energy-dispersive x-ray analysis and electron microprobe analysis confirmed that at higher temperature, the diffusion of Cu atoms from copper plate towards the braze-zone was faster than that of Ni atoms from nickel coating. Helium leak rate of the order 10‑11 Pa m3/s was obtained for the crack-free joint, whereas this value was higher than 10‑4 Pa m3/s for the joint having crack. The shear strength of the joint was found to decrease considerably due to the presence of crack.
- Publication:
-
Journal of Materials Engineering and Performance
- Pub Date:
- March 2017
- DOI:
- Bibcode:
- 2017JMEP...26.1085C
- Keywords:
-
- brazing;
- copper;
- electron;
- failure analysis;
- joining;
- microscopy;
- stainless;
- steel