Estimating Hyrdologic Properties of Groundwater Wells Using Tracer Pulse Dynamic Flow Profiling
Abstract
Traditional groundwater well design places the pump intake above the top of the well screen. It is common in this case to design the well screen for uniform entrance velocity along the profile of the well screen, even though non-uniform flow may occur. Particularly in the case where the pump is set near the very top or bottom of the well, there are instances where the zonal testing with a test pump indicates favorable water quality at one pump depth of the groundwater production well, and the water quality results yielded from the well at another depth are not compliant with federal and state regulatory limits for various naturally occurring and anthropogenic compounds. Well bore flow velocity and chemistry were determined using the USGS Tracer Pulse Dynamic Flow Profiling method along the length of well screens, while varying the pump depth. The information was then used to perform a flow and chemical mass balance to characterize the distribution of flow and chemical contribution, groundwater well screen entrance velocities, and hydrologic parameters. The presented results show pump placement affecting the average chemical discharge, and entrance velocities along the length of well screens.
- Publication:
-
AGU Fall Meeting Abstracts
- Pub Date:
- December 2016
- Bibcode:
- 2016AGUFMNS41B1918M
- Keywords:
-
- 1829 Groundwater hydrology;
- HYDROLOGYDE: 1835 Hydrogeophysics;
- HYDROLOGYDE: 1880 Water management;
- HYDROLOGY