Influence of Wind Velocity Fluctuation on Air Temperature Difference between the Fan and Ground Levels and the Effect of Frost Protective Fan Operation
Abstract
We invested the influence of wind velocity fluctuation on air temperature difference between the fan (4.8 m) and ground levels (0.5 m) and the effect of frost protective fan operation in order to develop a new method to reduce electricity consumption due to frost protective fan operation. The results of the investigations are summarized as follows:
(1) Air temperature difference between the fan (4.8 m) and ground levels (0.5 m) was decreased following an increase in wind velocity, and the difference was less than 1°C for a wind velocity more than 3.0 m/s at a height of 6.5 m. (2) When the wind velocity was more than 2-3 m/s, there was hardly any increase in the temperature of the leaves. In contrast, when the wind velocity was less than 2-3 m/s, an increase in the temperature of the leaves was observed. Based on these results, it is possible that when the wind velocity is greater than 2-3 m, it prevents thermal inversion. Therefore, there would be no warmer air for the frost protective fan to return to the tea plants and the air turbulence produced by the frost protective fan would not reach the plants under the windy condition.- Publication:
-
Chagyo Kenkyu Hokoku (Tea Research Journal)
- Pub Date:
- 2011
- DOI:
- 10.5979/cha.2008.106_15
- Bibcode:
- 2011CKH..200810615A
- Keywords:
-
- frost protection;
- frost protective fan;
- thermal inversion;
- wind velocity;
- tea plant