Influence of the heater material on the critical heat load at boiling of liquids on surfaces with different sizes
Abstract
Data on critical heat loads qcr for the saturated and unsaturated pool boiling of water and ethanol under atmospheric pressure are reported. It is found experimentally that the critical heat load does not necessarily coincide with the heat load causing burnout of the heater, which should be taken into account. The absolute values of qcr for the boiling of water and ethanol on copper surfaces 65, 80, 100, 120, and 200 μm in diameter; tungsten surface 100 μm in diameter; and nichrome surface 100 μm in diameter are obtained experimentally.
- Publication:
-
Journal of Technical Physics
- Pub Date:
- May 2010
- DOI:
- 10.1134/S1063784210050087
- Bibcode:
- 2010JTePh..55..645A
- Keywords:
-
- Heating Surface;
- Heat Load;
- Tungsten Wire;
- Boiling Curve;
- Manganine