Development of the 2-MV Injector for HIF
Abstract
The 2-MV Injector consists of a 17-cm-diameter surface ionization source, an extraction diode, and an electrostatic quadrupole (ESQ) accelerator, with maximum current of 0.8 A of potassium beam at 2 MeV. Previous performance of the Injector produced a beam with adequate current and emittance but with a hollow profile at the end of the ESQ section. We have examined the profile of the beam as it leaves the diode. The measured nonuniform beam density distribution qualitatively agrees with EGUN simulation. Implications for emittance growth in the post acceleration and transport phase will be investigated.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- May 2001
- DOI:
- 10.1016/S0168-9002(01)00147-4
- Bibcode:
- 2001NIMPA.464..592B