A new detector for low Pt physics
Abstract
Elastic pp (or poverlinep) scattering at microradian angles provides a measurement of the total pp (or poverlinep) cross sectio elastic scattering cross section with t (the square of the momentum transfer) and the ratio of real to imaginary scattering amplitudes, as well as an absolute luminosity calibration. A detector is proposed which can measure elastic scattering and small angle processes which are usually missed by a typical 4π detector. The detector consists of a bundle of scintillating fibers. Images from these fibers are transported via glass fiber optics and intensified with two proximity focused image intensifiers. Images are then reduced via an image taper and read out with a charge coupled device (CCD).
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- December 1992
- DOI:
- 10.1016/0168-9002(92)90326-Y
- Bibcode:
- 1992NIMPA.323..419D