JPS heater and sensor lightning qualification
Abstract
Simulated lightning strike testing of the Redesigned Solid Rocket Motor (RSRM) field joint protection system heater assembly was performed at Thiokol Corp., Wendover Lightning Facility. Testing consisted of subjecting the lightning evaluation test article to simulated lightning strikes and evaluating the effects of heater cable transients on cables within the systems tunnel. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by transients from all cables external to the systems tunnel, was 92 amperes. The maximum open-circuit voltage coupled was 316 volts. The maximum short circuit current coupled onto a United Space Boosters, Inc. operational flight cable within the systems tunnel, induced by heater power cable transients only, was 2.7 amperes; the maximum open-circuit voltage coupled was 39 volts. All heater power cable induced coupling was due to simulated lightning discharges only, no heater operating power was applied during the test. The results showed that, for a worst-case lightning discharge, the heater power cable is responsible for a 3.9 decibel increase in voltage coupling to operational flight cables within the systems tunnel. Testing also showed that current and voltage levels coupled onto cables within the systems tunnel are partially dependant on the relative locations of the cables within the systems tunnel.
- Publication:
-
Final Test Report Thiokol Corp
- Pub Date:
- October 1989
- Bibcode:
- 1989thco.rept.....C
- Keywords:
-
- Electromagnetic Coupling;
- Electromagnetic Shielding;
- Lightning;
- Rocket Engine Cases;
- Short Circuits;
- Transmission Lines;
- Current Regulators;
- Solid Propellant Rocket Engines;
- Space Transportation System;
- Transmission Loss;
- Voltage Regulators;
- Instrumentation and Photography