Arc discharge conditioning test on the Oak Ridge 25 URC accelerator
Abstract
A hydrogen arc discharge has been run in the top five units (fifteen 20 cm tube sections) of the ORNL tandem accelerator to test the effectiveness of this method of cleaning the high voltage electrodes. The discharge was maintained in both the high and low-energy tubes for a period of 6 hours. The arc current in each tube was 4.0 A and the hydrogen pressure was nominally 100 mTorr. The arc discharge does not appear to have significantly affected the operating voltage of the top five units of the accelerator. However, the voltage conditioning behavior of the tested units is markedly different.