Results of studies of industrial radio frequency noise in the 10-150 kHz range
Abstract
Radio frequency interference in the 10-150 kHz range from different types of electrical and electronic equipment was measured. Measurements were performed on high power asynchronous machines, fluorescent lamps, low power electric motors, static converters and rectifiers with thyristors, communication cables, computers, electric welding equipment, electric transportation systems, power transmission lines, and HF industrial and medical equipment. Some recommendations on noise reduction are presented.
- Publication:
-
4th Miedzynarodowe Sympozjum EMC
- Pub Date:
- 1978
- Bibcode:
- 1978pwit.symp...55K
- Keywords:
-
- Electric Equipment Tests;
- Electromagnetic Compatibility;
- Electronic Equipment;
- Radio Frequency Interference;
- Electric Motors;
- Field Strength;
- Noise Reduction;
- Thyristors;
- Transmission Lines;
- Communications and Radar