Analysis on Two-phase Heat Transfer Characteristics in Horizontal Mini-tubes
Abstract
The two-phase heat transfer characteristics of degassed water flow boiling in horizontal mini-tubes are experimentally investigated in this paper. The inner diameters (di) of the tubes are 1.2mm, 1.6mm, and 2.0mm. Experiments are conducted with heat fluxes between 1.5kW/m2 and 155.75kW/m2 at mass fluxes of 21.19, 42.39, and 84.77kg/(m2s). The boiling curves of the three tubes are obtained. Incipient hysteresis is observed only in the tube with di = 1.2mm. Two-phase dominant heat transfer mechanisms are analyzed in the tubes with di = 1.2mm and di = 2.0mm based on the curves of local heat transfer coefficient versus vapor quality and the visualization results. The trend of peak value of the local heat transfer coefficient versus heat flux at different mass fluxes in the tube with di = 1.2mm is discussed in accordance with the thickness variation of the liquid film in annular flow.
- Publication:
-
Journal of Physics Conference Series
- Pub Date:
- July 2021
- DOI:
- 10.1088/1742-6596/1985/1/012036
- Bibcode:
- 2021JPhCS1985a2036A
- Keywords:
-
- Two-phase;
- Heat Transfer Characteristics;
- Mini-tube