Measurement of the O2 Dissociation Fraction in RF Low Pressure O2/Ar Plasma Using Optical Emission Spectrometry
Abstract
Measurement of the oxygen dissociation fraction in RF low pressure oxygen/argon plasma using optical emission spectrometry is presented. The oxygen dissociation fraction and its evolutions as functions of operational parameters were determined using argon as the actinometer. At a pressure of 30 Pa, the oxygen dissociation fraction decreased from 13.4% to 9.5% as the input power increased from 10 W to 70 W. At an input power of 50 W, the oxygen dissociation fraction decreased from 12.3% to 7.7% when the gas pressure increased from 10 Pa to 40 Pa. The influences of operational parameters on the generation of atomic oxygen were also discussed.
- Publication:
-
Plasma Science and Technology
- Pub Date:
- August 2011
- DOI:
- 10.1088/1009-0630/13/4/14
- Bibcode:
- 2011PlST...13..458L