High Resolution Monochromatic X-Ray Imaging of Targets Irradiated by the Nike KrF Laser
Abstract
Planar CH foils were accelerated by the main Nike laser driving beams and were backlit by Si plasmas. A spherically-bent quartz crystal (R=25cm, 2d=6.68703 Åimaged the radiation of He-like Si resonance line that was transmitted through the target foil. The intensity of the backlighted image (6 beams, 250 J) was 160 times greater than the self emission from a driven CH foil. The magnified (X9.6) images on DEF film had the resolution about 5 μ m (3 μ m with R=10cm). The resulting 10 μ m spatial resolution in the gated images was determined by 100 μ m resolution of the framing camera. Images of CH targets were recorded 2 nsec after the peak of the laser pulse and revealed the growth of Rayleigh-Taylor instabilities that were seeded by patterns with amplitude as small as 0.25 μ m. The image of driven smooth CH target was quite smooth compared to those of the patterned CH foil. A future imaging instrument will have multiple backlighter plasmas and better quality bent crystals that can be bent into a toroidal shape. Up to four images with higher magnification and spatial resolution of 5 μ m may be recorded on the framing camera. This work supported by the US Department of Energy