A start-timing detector for the collider experiment PHENIX at RHIC-BNL
Abstract
We describe a start-timing detector for the PHENIX experiment at the relativistic heavy-ion collider RHIC. The role of the detector is to detect a nuclear collision, provide precise time information with an accuracy of 50 ps, and determine the collision point along the beam direction with a resolution of a few cm. Technical challenges are that the detector must be operational in a wide particle-multiplicity range in a high radiation environment and a strong magnetic field. We present the performance of the prototype and discuss the final design of the detector.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- February 1998
- DOI:
- 10.1016/S0168-9002(98)00307-6
- arXiv:
- arXiv:physics/9802024
- Bibcode:
- 1998NIMPA.411..238I
- Keywords:
-
- Physics - Instrumentation and Detectors;
- High Energy Physics - Experiment
- E-Print:
- 12 pages, LaTeX, 9 gif and 4 ps figures. Submitted to NIM A