Direct and absolute temperature mapping and heat transfer measurements in diode-end-pumped Yb:YAG
Abstract
We report on direct and absolute temperature measurements in a diode-end-pumped Yb:YAG crystal, using a calibrated infrared camera, with a 60 μm spatial resolution. The heat transfer coefficient has been measured, for the first time to our knowledge, with four different types of thermal contact (H=0.25, 0.28, 0.9, and 2.0 for bare contact, graphite layer, indium foil, and heat sink grease respectively). The dynamics of thermal effects are also presented.
- Publication:
-
Applied Physics B: Lasers and Optics
- Pub Date:
- July 2004
- DOI:
- arXiv:
- arXiv:physics/0610061
- Bibcode:
- 2004ApPhB..79..221C
- Keywords:
-
- Heat Transfer;
- Graphite;
- Transfer Coefficient;
- Heat Transfer Coefficient;
- Temperature Measurement;
- Physics - Optics
- E-Print:
- Applied Physics B 79 (2004) 221-224