An insulating grid spacer for large-area MICROMEGAS chambers
Abstract
We present a novel design for large-area gaseous detectors based on the MICROMEGAS technology. This technology incorporates an insulating grid, sandwiched between the micro-mesh and the anode-pad plane, which provides a uniform 200 μm amplification gap. The uniformity of the amplification gap thickness has been verified. The gain performances of the detector are presented and compared to the values obtained with detectors using cylindrical micro spacers. The new design presents several technical and financial advantages.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- April 2002
- DOI:
- arXiv:
- arXiv:physics/0103027
- Bibcode:
- 2002NIMPA.481..144B
- Keywords:
-
- Physics - Instrumentation and Detectors
- E-Print:
- 7 pages, 4 figures, Letter to NIM Editor