Use of Coherent Transition Radiation to Set Up the APS RF Thermionic Gun to Produce High-Brightness Beams for SASE FEL Experiments
Abstract
We describe use of the Advanced Photon Source (APS) rf thermionic gun, alpha magnet beamline, and linac to produce a stable high-brightness beam in excess of 100 amperes peak current with normalized emittance of 10 pi mm-mrad. To obtain peak currents greater than 100 amperes, the rf gun system must be tuned to produce a FWHM bunch length on the order of 350 fs. Bunch lengths this short are measured using coherent transition radiation (CTR) produced when the rf gun beam, accelerated to 40 MeV, strikes a metal foil. The CTR is detected using a Golay detector attached to one arm of a Michelson interferometer. The alpha magnet current and gun rf phase are adjusted so as to maximize the CTR signal at the Golay detector, which corresponds to the minimum bunch length. The interferometer is used to measure the autocorrelation of the CTR radiation. The minimum phase approximation is used to derive the bunch profile from the autocorrelation. The high-brightness beam is accelerated to 217 MeV and used to produce SASE in five APS undulators installed in the Low- Energy Undulator Test Line (LEUTL) experiment hall. Initial optical measurements showed a gain length of 1.3 m at 530 nm. * Work supported by U. S. Department of Energy, Office of Basic Energy Sciences, under Contract No. W-31-109-ENG-38.
- Publication:
-
Linac 2000
- Pub Date:
- 2000
- DOI:
- arXiv:
- arXiv:physics/0008116
- Bibcode:
- 2000lina.conf..134S
- Keywords:
-
- Physics - Accelerator Physics
- E-Print:
- LINAC2000 MOB17 3 pages 8 figures