Further study of CdWO 4 crystal scintillators as detectors for high sensitivity 2β experiments: Scintillation properties and pulse-shape discrimination
Abstract
Energy resolution, non-proportionality in the scintillation response, α/β ratio, pulse shape for γ rays and α particles were studied with CdWO 4 crystal scintillators. Some indication for a difference in the emission spectra for γ rays and α particles was observed. No dependence of CdWO 4 pulse shape on emission spectrum wavelengths under laser, α particles and γ ray excitation was observed. Dependence of scintillation pulse shape for γ quanta and α particles and pulse-shape discrimination ability on temperature was measured in the range of 0-24 °C.