Construction and performance of a micro-pattern stereo detector with two gas electron multipliers
Abstract
The construction of a micro-pattern gas detector of dimensions 40×10 cm2 is described. Two gas electron multiplier foils (GEM) provide the internal amplification stages. A two-layer readout structure was used, manufactured using the same technology as the GEM foils. The strips of each layer cross at an effective crossing angle of 6.7° and have a 406 μm pitch. The performance of the detector has been evaluated in a muon beam at CERN using a silicon telescope as reference system. The position resolutions of two orthogonal coordinates are measured to be 50 μm and 1 mm, respectively. The muon detection efficiency for two-dimensional space points reaches 96%.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- June 2002
- DOI:
- 10.1016/S0168-9002(01)02109-X
- arXiv:
- arXiv:hep-ex/0110008
- Bibcode:
- 2002NIMPA.485..477B
- Keywords:
-
- High Energy Physics - Experiment
- E-Print:
- 21 pages, 17 figures