Force measurements of a superconducting-film actuator for a cryogenic interferometric gravitational-wave detector
Abstract
We measured forces applied by an actuator with a YBa2Cu3O7 (YBCO) film at near 77 K for the Large-scale Cryogenic Gravitational-wave Telescope (LCGT) project. An actuator consisting of both a YBCO film of 1.6 μm thickness and 0.81 cm2 area and a solenoid coil exerted a force of up to 0.2 mN on a test mass. The presented actuator system can be used to displace the mirror of LCGT for fringe lock of the interferometer.
- Publication:
-
Cryogenics
- Pub Date:
- July 2003
- DOI:
- arXiv:
- arXiv:gr-qc/0206011
- Bibcode:
- 2003Cryo...43..425S
- Keywords:
-
- Gravitational wave detector;
- High-Tc superconductor;
- Actuator;
- General Relativity and Quantum Cosmology
- E-Print:
- 9 pages, 3 figures