Characterization of the glass transition in vitreous silica by temperature scanning small-angle X-ray scattering
Abstract
The temperature dependence of the X-ray scattering in the region below the first sharp diffraction peak was measured for silica glasses with low and high OH content (GE-124 and Corning 7980). Data were obtained upon scanning the temperature at 10, 40 and 80 K/min between 400 K and 1820 K. The measurements resolve, for the first time, the hysteresis between heating and cooling through the glass transition for silica glass, and the data have a better signal-to-noise ratio than previous light scattering and differential thermal analysis data. For the glass with the higher hydroxyl concentration, the glass transition is broader and at a lower temperature. Fits of the data to the Adam-Gibbs-Fulcher equation provide updated kinetic parameters for this very strong glass. The temperature derivative of the observed X-ray scattering matches that of light scattering to within 14%.
- Publication:
-
EPL (Europhysics Letters)
- Pub Date:
- April 2005
- DOI:
- 10.1209/epl/i2004-10481-1
- arXiv:
- arXiv:cond-mat/0503439
- Bibcode:
- 2005EL.....70..211B
- Keywords:
-
- Condensed Matter - Disordered Systems and Neural Networks
- E-Print:
- EurophysicsLetters, in press