Development of silicon strip detectors for a medium energy gamma-ray telescope
Abstract
We report on the design, production, and testing of advanced double-sided silicon strip detectors under development at the Max-Planck-Institute as part of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are designed to form a stack, the ``tracker,'' with the goal of recording the paths of energetic electrons produced by Compton-scatter and pair-production interactions. Each layer of the tracker is composed of a 3×3 array of 500μm thick silicon wafers, each 6cm×6cm and fitted with 128 orthogonal p and n strips on opposite sides (470μm pitch). The strips are biased using the punch-through principle and AC-coupled via metal strips separated from the strip implant by an insulating oxide/nitride layer. The strips from adjacent wafers in the 3×3 array are wire-bonded in series and read out by 128-channel TA1.1 ASICs, creating a total 19cm×19cm position-sensitive area. At 20°C a typical energy resolution of 15-20keV FWHM, a position resolution of 290μm, and a time resolution of ~1μs is observed.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- October 2003
- DOI:
- 10.1016/S0168-9002(03)01897-7
- arXiv:
- arXiv:astro-ph/0302500
- Bibcode:
- 2003NIMPA.512..220B
- Keywords:
-
- Silicon strip detectors;
- Gamma-ray detectors;
- X-ray detectors;
- Gamma-ray astronomy;
- Astrophysics
- E-Print:
- 9 pages, 13 figures, to appear in NIM-A (Proceedings of the 9th European Symposium on Semiconductor Detectors)