Phase-resolved Crab Studies with a Cryogenic Transition-Edge Sensor Spectrophotometer
Abstract
We are developing time- and energy-resolved near-IR/optical/UV photon detectors based on sharp superconducting-normal transition edges in thin films. We report observations of the Crab pulsar made during prototype testing at the McDonald 2.7 m with a fiber-coupled transition-edge sensor (TES) system. These data show substantial (δα~0.3), rapid variations in the spectral index through the pulse profile, with a strong phase-varying IR break across our energy band. These variations correlate with X-ray spectral variations, but no single synchrotron population can account for the full spectral energy distribution. We also describe test spectrophotopolarimetry observations probing the energy dependence of the polarization sweep; this may provide a new key to understanding the radiating particle population.
- Publication:
-
The Astrophysical Journal
- Pub Date:
- December 2001
- DOI:
- arXiv:
- arXiv:astro-ph/0108240
- Bibcode:
- 2001ApJ...563..221R
- Keywords:
-
- Instrumentation: Detectors;
- pulsars: individual (PSR B0531+21);
- Astrophysics
- E-Print:
- 12 pages, 10 figures -- to appear in ApJ V562