A liquid-phase loop-mode argon purification system
Abstract
Noble gas and liquid detectors rely on high chemical purity for successful operation. While gaseous purification has emerged as a reliable method of producing high-purity noble fluids, the requirement for large mass flows drives the development of liquid-phase purification. We constructed a medium-scale liquid argon (LAr) purification system based on a copper catalyst and 4 Å molecular sieve capable of purifying 1 t of commercial LAr 5.0 to a long effective triplet lifetime of τ3 ∼ 1.3 μs. We further demonstrate that a quenched effective triplet lifetime of τ3 ∼ 1 μs, due to contamination by air, can be recovered in loop-mode purification to τ3 ∼ 1.3 μs after > 20 volume exchanges.
- Publication:
-
Journal of Instrumentation
- Pub Date:
- March 2024
- DOI:
- 10.1088/1748-0221/19/03/C03030
- arXiv:
- arXiv:2311.18697
- Bibcode:
- 2024JInst..19C3030V
- Keywords:
-
- Gas systems and purification;
- Noble liquid detectors (scintillation;
- ionization;
- double-phase);
- Physics - Instrumentation and Detectors;
- Astrophysics - Instrumentation and Methods for Astrophysics
- E-Print:
- 8 pages, 2 figures, contribution to LIDINE2023 v2: Added discussion of N2-trapping capability of purifier. Fixed typos, improved text/figure style, and added a reference