A comparative study of deconvolution techniques for quantum-gas microscope images
Abstract
Quantum-gas microscopes are used to study ultracold atoms in optical lattices at the single-particle level. In these systems atoms are localised on lattice sites with separations close to or below the diffraction limit. To determine the lattice occupation with high fidelity, a deconvolution of the images is often required. We compare three different techniques, a local iterative deconvolution algorithm, Wiener deconvolution and the Lucy-Richardson algorithm, using simulated microscope images. We investigate how the reconstruction fidelity scales with varying signal-to-noise ratio, lattice filling fraction, varying fluorescence levels per atom, and imaging resolution. The results of this study identify the limits of singe-atom detection and provide quantitative fidelities which are applicable for different atomic species and quantum-gas microscope setups.
- Publication:
-
New Journal of Physics
- Pub Date:
- August 2023
- DOI:
- 10.1088/1367-2630/aced65
- arXiv:
- arXiv:2207.08663
- Bibcode:
- 2023NJPh...25h3036L
- Keywords:
-
- quantum gas microscope;
- quantum gas;
- imaging;
- Condensed Matter - Quantum Gases;
- Physics - Atomic Physics;
- Physics - Data Analysis;
- Statistics and Probability
- E-Print:
- New J. Phys. 25, 083036 (2023)