Brillouin backaction thermometry for modal temperature control
Abstract
Stimulated Brillouin scattering provides optical gain for efficient and narrow-linewidth lasers in high-Q microresonator systems. However, the thermal dependence of the Brillouin process, as well as the microresonator, impose strict temperature control requirements for long-term frequency-stable operation. Here, we study Brillouin back action and use it to both measure and phase-sensitively lock modal temperature to a reference temperature defined by the Brillouin phase-matching condition. At a specific lasing wavelength, the reference temperature can be precisely set by adjusting resonator free spectral range. This backaction control method is demonstrated in a chip-based Brillouin laser, but can be applied in all Brillouin laser platforms. It offers a new approach for frequency-stable operation of Brillouin lasers in atomic clock, frequency metrology, and gyroscope applications.
- Publication:
-
Optica
- Pub Date:
- July 2022
- DOI:
- 10.1364/OPTICA.459082
- arXiv:
- arXiv:2205.07181
- Bibcode:
- 2022Optic...9..701L
- Keywords:
-
- Physics - Optics;
- Physics - Instrumentation and Detectors