Recent Improvements in the Beam Capture at Fermilab Booster for High Intensity Operation
Abstract
The Fermilab Booster uses multi-turn beam injection with all its cavities phased such that beam sees a net zero RF voltage even when each station is at the same maxi-mum voltage. During beam capture the RF voltage is increased slowly by using its paraphase system. At the end of the capture the feedback is turned on for beam acceleration. It is vital for present operations as well as during the PIP-II era that both the HLRF and LLRF systems provide the proper intended phase and RF voltage to preserve the longitudinal emittance from injection to extraction. In this paper, we describe the original architecture of the cavity phase distribution, our recent beam-based RF phase measurements, observed significant deviation in the relative phases between cavities and correction effort. Results from the improved capture for high intensity beam are also presented.
- Publication:
-
arXiv e-prints
- Pub Date:
- October 2021
- DOI:
- 10.48550/arXiv.2110.09713
- arXiv:
- arXiv:2110.09713
- Bibcode:
- 2021arXiv211009713B
- Keywords:
-
- Physics - Accelerator Physics
- E-Print:
- .pdf prepared on Windos10 from .docx document, 4 pages, 9 figures, to be published in "HB2021, 64th ICFA Advanced Beam Dynamics Workshop on High Intensity and High Brightness Hadron Beams, October 4-9, 2021