83Rb/Krm83 production and cross-section measurement with 3.4 MeV and 20 MeV proton beams
Abstract
Krm83, with a short lifetime, is an ideal calibration source for liquid xenon or liquid argon detectors. The Krm83 isomer can be generated through the decay of the 83Rb isotope, which is usually produced by proton beams bombarding natural krypton atoms. In this paper, we report a successful production of 83Rb/Krm83 with a proton beam energy of 3.4 MeV, and the first measurement of the production rate with such low-energy proton beams. Another production attempt is performed using the newly available 20 MeV proton beam in China, and the measured production rate is consistent with previous measurements. The produced Krm83 source has been successfully injected into the PandaX-II liquid xenon detector, yielding enough statistics for detector calibration.
- Publication:
-
Physical Review C
- Pub Date:
- January 2022
- DOI:
- 10.1103/PhysRevC.105.014604
- arXiv:
- arXiv:2102.02490
- Bibcode:
- 2022PhRvC.105a4604Z
- Keywords:
-
- Nuclear Experiment;
- Physics - Instrumentation and Detectors
- E-Print:
- 9 pages, 8 figures, version published on PRC