Technique for Rapid Mass Determination of Airborne Microparticles Based on Release and Recapture from an Optical Dipole Force Trap
Abstract
We describe a method for the rapid determination of the mass of particles confined in a free-space optical dipole force trap. The technique relies on direct imaging of drop-and-restore experiments without the need for a vacuum environment. In these experiments, the trapping light is rapidly shuttered with an acousto-optic modulator, causing the particle to be released from and subsequently recaptured by the trapping force. The trajectories of both the falls and restorations, imaged using a high-speed CMOS sensor, are combined to determine the particle mass. We corroborate these measurements using an analysis of position autocorrelation functions and the mean-square displacement of the trapped particles. We report a statistical uncertainty of less than 2% for masses on the order of 5 ×10-14kg using a data acquisition time of approximately 90 s.
- Publication:
-
Physical Review Applied
- Pub Date:
- August 2020
- DOI:
- 10.1103/PhysRevApplied.14.024017
- arXiv:
- arXiv:2006.12237
- Bibcode:
- 2020PhRvP..14b4017C
- Keywords:
-
- Physics - Applied Physics;
- Physics - Atomic Physics;
- Physics - Biological Physics;
- Physics - Optics
- E-Print:
- Phys. Rev. Applied 14, 024017 (2020)