Optical atomic clock comparison through turbulent air
Abstract
We use frequency-comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5-km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite nonstationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to 6 ×10-19 , showing that O-TWTFT can support free-space atomic clock comparisons below the 10-18 level.
- Publication:
-
Physical Review Research
- Pub Date:
- September 2020
- DOI:
- 10.1103/PhysRevResearch.2.033395
- arXiv:
- arXiv:2006.01306
- Bibcode:
- 2020PhRvR...2c3395B
- Keywords:
-
- Physics - Optics;
- Physics - Instrumentation and Detectors
- E-Print:
- Phys. Rev. Research 2, 033395 (2020)