Trace radioactive impurities in final construction materials for EXO-200
Abstract
We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of analytic techniques. The measurement sensitivities are among the best in the field. Construction of the EXO-200 detector has been concluded, and Phase-I data was taken from 2011 to 2014. The detector's extremely low background implicitly verifies the measurements and the analysis assumptions made during construction and reported in this paper.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- November 2017
- DOI:
- 10.1016/j.nima.2017.04.049
- arXiv:
- arXiv:1703.10799
- Bibcode:
- 2017NIMPA.871..169L
- Keywords:
-
- Radiopurity;
- Ultra-trace analysis;
- Neutron activation analysis;
- Mass spectrometry;
- Mass spectroscopy;
- Germanium counting;
- Alpha counting;
- Low background;
- Double beta decay;
- EXO;
- EXO-200;
- Physics - Instrumentation and Detectors;
- Nuclear Experiment
- E-Print:
- 28 pages, 5 figures