Timing performance of a double layer diamond detector
Abstract
In order to improve the time precision of detectors based on diamonds sensors we have built a detector with two scCVD layers connected in parallel to the same amplifier. This work describes the design and the first measurements of such a prototype performed on a particle beam at CERN. With this different configuration we have obtained an improvement larger than a factor of 1.6-1.7 for the timing precision of the measurement when compared to a one layer scCVD diamond detector.