Laser-Frequency Stabilization via a Quasimonolithic Mach-Zehnder Interferometer with Arms of Unequal Length and Balanced dc Readout
Abstract
Low-frequency high-precision laser interferometry is subject to excess laser-frequency-noise coupling via arm-length differences which is commonly mitigated by locking the frequency to a stable reference system. This approach is crucial to achieve picometer-level sensitivities in the 0.1-mHz to 1-Hz regime, where laser-frequency noise is usually high and couples into the measurement phase via arm-length mismatches in the interferometers. Here we describe the results achieved by frequency stabilizing an external cavity diode laser to a quasimonolithic unequal arm-length Mach-Zehnder interferometer readout at midfringe via balanced detection. We find this stabilization scheme to be an elegant solution combining a minimal number of optical components, no additional laser modulations, and relatively low-frequency-noise levels. The Mach-Zehnder interferometer is designed and constructed to minimize the influence of thermal couplings and to reduce undesired stray light using the optical simulation tool ifocad. We achieve frequency-noise levels below 100 Hz /√{Hz } at 1 Hz and are able to demonstrate the LISA frequency prestabilization requirement of 300 Hz /√{Hz } down to frequencies of 100 mHz by beating the stabilized laser with an iodine-locked reference.
- Publication:
-
Physical Review Applied
- Pub Date:
- February 2017
- DOI:
- 10.1103/PhysRevApplied.7.024027
- arXiv:
- arXiv:1610.09684
- Bibcode:
- 2017PhRvP...7b4027G
- Keywords:
-
- Physics - Instrumentation and Detectors
- E-Print:
- 6 pages, 6 figures, published in Phyiscal Review Applied