Detection system for neutron β decay correlations in the UCNB and Nab experiments
Abstract
We describe a detection system designed for precise measurements of angular correlations in neutron β decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for β electron detection with energy thresholds below 10 keV, energy resolution of ∼3 keV FWHM, and rise time of ∼50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of β particles and recoil protons from neutron β decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments to determine the neutron β decay parameters B, a, and b.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- March 2017
- DOI:
- 10.1016/j.nima.2016.12.030
- arXiv:
- arXiv:1607.02656
- Bibcode:
- 2017NIMPA.849...83B
- Keywords:
-
- Silicon detector;
- Neutron beta decay;
- Ultracold neutrons;
- Physics - Instrumentation and Detectors;
- Nuclear Experiment
- E-Print:
- Copyright 2016. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/