PMT overshoot study for the JUNO prototype detector
Abstract
The quality of PMT signals is crucial for large-size and high-precision neutrino experiments, but most of these experiments are affected by the overshoot of PMT signals from the positive HV-single cable scheme. Overshoot affects the trigger, dead time and charge measurement from a detector. For the JUNO prototype detector, we have performed a detailed study and calculation on PMT signal overshoot to control the ratio of overshoot to signal amplitude to ∼1%, with no effect on other PMT parameters.
Supported by Strategic Priority Research Program A-JUNO, High Energy Physics Experiment and Detector R&D and National Natural Science Foundation of China- Publication:
-
Chinese Physics C