Monte Carlo simulation of prompt γ-ray spectra from depleted uranium under D-T neutron irradiation and electron recoil spectra in a liquid scintillator detector
Abstract
To overcome the problem of inefficient computing time and unreliable results in MCNP5 calculation, a two-step method is adopted to calculate the energy deposition of prompt γ-rays in detectors for depleted uranium spherical shells under D-T neutron irradiation. In the first step, the γ-ray spectrum for energy below 7 MeV is calculated by MCNP5 code; secondly, the electron recoil spectrum in a BC501A liquid scintillator detector is simulated based on EGSnrc Monte Carlo Code with the γ-ray spectrum from the first step as input. The comparison of calculated results with experimental ones shows that the simulations agree well with experiment in the energy region 0.4-3 MeV for the prompt γ-ray spectrum and below 4 MeVee for the electron recoil spectrum. The reliability of the two-step method in this work is validated.
Supported by the National Natural Science Foundation of China (91226104) and National Special Magnetic Confinement Fusion Energy Research, China (2015GB108001)- Publication:
-
Chinese Physics C
- Pub Date:
- March 2016
- DOI:
- 10.1088/1674-1137/40/3/036201
- arXiv:
- arXiv:1507.03389
- Bibcode:
- 2016ChPhC..40c6201Q
- Keywords:
-
- Physics - Instrumentation and Detectors
- E-Print:
- 9 pages, 8 figures, 1 table