Synchronous Spin-Exchange Optical Pumping
Abstract
We demonstrate a new approach to precision NMR with hyperpolarized gases designed to mitigate NMR shifts due to the alkali spin-exchange field. The NMR bias field is implemented as a sequence of alkali (Rb) 2 π pulses, allowing the Rb polarization to be optically pumped transverse to the bias field. When the Rb polarization is modulated at the noble-gas (Xe) NMR resonance, spin-exchange collisions buildup a precessing transverse Xe polarization. We study and mitigate novel NMR broadening effects due to the oscillating spin-exchange field. Spin-exchange frequency shifts are suppressed 2500 ×, and Rb magnetometer gain measurements project photon shot-noise limited NMR frequency uncertainties below 10 nHz /√{Hz } .
- Publication:
-
Physical Review Letters
- Pub Date:
- December 2015
- DOI:
- 10.1103/PhysRevLett.115.253001
- arXiv:
- arXiv:1506.08797
- Bibcode:
- 2015PhRvL.115y3001K
- Keywords:
-
- 32.30.Dx;
- 07.55.Ge;
- 32.80.Xx;
- Magnetic resonance spectra;
- Magnetometers for magnetic field measurements;
- Level crossing and optical pumping;
- Physics - Atomic Physics
- E-Print:
- 4 pages, 4 figures