Test of candidate light distributors for the muon (g - 2) laser calibration system
Abstract
The new muon (g-2) experiment E989 at Fermilab will be equipped with a laser calibration system for all the 1296 channels of the calorimeters. An integrating sphere and an alternative system based on an engineered diffuser have been considered as possible light distributors for the experiment. We present here a detailed comparison of the two based on temporal response, spatial uniformity, transmittance and time stability.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- July 2015
- DOI:
- 10.1016/j.nima.2015.03.071
- arXiv:
- arXiv:1504.00132
- Bibcode:
- 2015NIMPA.788...43A
- Keywords:
-
- Electromagnetic calorimeter;
- Integrating sphere;
- Diffuser;
- Physics - Instrumentation and Detectors;
- High Energy Physics - Experiment
- E-Print:
- accepted to Nucl.Instrum.Meth. A