Sensitivity of the Heat Transfer Coefficient Calculation
Abstract
The purpose of the Liscic/Petrofer probe is to determine the cooling intensity during liquid quenching in laboratory and workshop environments. The surface heat transfer coefficient is calculated by the one-dimensional finite volume method from the smoothed temperature curve, measured at a near-surface point in the probe. Smoothed reference temperature curves for oil and water, based on measurements made by the probe, are used in a series of numerical experiments to investigate the sensitivity of the calculation with respect to various input parameters of the problem, such as: thermal properties of the material, the near-surface thermocouple position, and the diameter of the probe. These results are relevant for other liquid quenchants, at least qualitatively, if not quantitatively. A similar type of analysis is conducted with respect to the variation of numerical simulation parameters in the finite volume method---the choice of space and time steps for problem discretization. When the input curves are sufficiently smooth, the method itself is very reliable.
- Publication:
-
arXiv e-prints
- Pub Date:
- January 2014
- DOI:
- arXiv:
- arXiv:1401.2983
- Bibcode:
- 2014arXiv1401.2983S
- Keywords:
-
- Condensed Matter - Materials Science;
- Mathematics - Numerical Analysis;
- 80A20;
- 80A23 (Primary) 65M32 (Secondary)
- E-Print:
- 40 pages, 46 figures, submitted to Materials Performance and Characterization