Characterization and modeling of a low background HPGe detector
Abstract
A high efficiency, low background counting setup has been made at TIFR consisting of a special HPGe detector (~ 70 %) surrounded by a low activity copper+lead shield. Detailed measurements are performed with point and extended geometry sources to obtain a complete response of the detector. An effective model of the detector has been made with GEANT4 based Monte Carlo simulations which agrees with experimental data within 5%. This setup will be used for qualification and selection of radio-pure materials to be used in a cryogenic bolometer for the study of Neutrinoless Double Beta Decay in 124Sn as well as for other rare event studies. Using this setup, radio-impurities in the rock sample from India-based Neutrino Observatory (INO) site have been estimated.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- May 2014
- DOI:
- 10.1016/j.nima.2014.01.064
- arXiv:
- arXiv:1311.4779
- Bibcode:
- 2014NIMPA.745..119D
- Keywords:
-
- HPGe detector;
- Monte Carlo simulation;
- Low background measurements;
- Physics - Instrumentation and Detectors;
- Nuclear Experiment
- E-Print:
- 23 pages, 13 figures, re-submitted to NIM A (minor changes in text, figures and table)