Overlap Technique for End-Cap Seals on Cylindrical Magnetic Shields
Abstract
We present results from studies of the effectiveness of an overlap technique for forming a magnetic seal across a gap at the boundary between a cylindrical magnetic shield and an end-cap. In this technique a thin foil of magnetic material overlaps the two surfaces, thereby spanning the gap across the cylinder and the end-cap, with the magnetic seal then formed by clamping the thin magnetic foil to the surfaces of the cylindrical shield and the end-cap on both sides of the gap. In studies with a prototype 31-cm diameter, 91-cm long, 0.16-cm thick cylindrical magnetic shield and flared end-cap, the magnetic shielding performance of our overlap technique is comparable to that obtained with the conventional method in which the end-cap is placed in direct lapped contact with the cylindrical shield via through bolts or screws.
- Publication:
-
IEEE Transactions on Magnetics
- Pub Date:
- January 2013
- DOI:
- 10.1109/TMAG.2012.2215047
- arXiv:
- arXiv:1307.0866
- Bibcode:
- 2013ITM....49..651M
- Keywords:
-
- Physics - Instrumentation and Detectors
- E-Print:
- 4 pages, 5 figures