Measurement of shorter-than-skin-depth acoustic pulses in a metal film via transient reflectivity
Abstract
The detection of ultrashort laser-generated acoustic pulses at a metal surface and the reconstruction of the acoustic strain profile are investigated. A 2 ps-long acoustic pulse generated in an SrRuO3 layer propagates through an adjacent gold layer and is detected at its surface by a reflected probe pulse. We show that the intricate shape of the transient reflectivity waveform and the ability to resolve acoustic pulses shorter than the optical skin depth are controlled by a single parameter, which is determined by the ratio of the real and imaginary parts of the photoelastic constant of the material. We also demonstrate a Fourier transform-based algorithm that can be used to extract acoustic strain profiles from transient reflectivity measurements.
- Publication:
-
Applied Physics Letters
- Pub Date:
- October 2013
- DOI:
- 10.1063/1.4826210
- arXiv:
- arXiv:1306.0641
- Bibcode:
- 2013ApPhL.103q3104M
- Keywords:
-
- acoustic pulses;
- Fourier transforms;
- gold;
- high-speed optical techniques;
- metallic thin films;
- strontium compounds;
- 68.35.Iv;
- 78.47.J-;
- Acoustical properties;
- Ultrafast pump/probe spectroscopy;
- Condensed Matter - Materials Science;
- Condensed Matter - Mesoscale and Nanoscale Physics;
- Physics - Optics
- E-Print:
- Appl. Phys. Lett. 103, 173104 (2013)