Abstract
The Cornell University energy recovery linac (ERL) photoinjector has recently demonstrated operation at 20 mA for approximately 8 hours, utilizing a multialkali photocathode deposited on a Si substrate. We describe the recipe for photocathode deposition, and will detail the parameters of the run. Post-run analysis of the photocathode indicates the presence of significant damage to the substrate, perhaps due to ion back-bombardment from the residual beam line gas. While the exact cause of the substrate damage remains unknown, we describe multiple surface characterization techniques (x-ray fluorescence spectroscopy, x-ray diffraction, atomic force, and scanning electron microscopy) used to study the interesting morphological and crystallographic features of the photocathode surface after its use for high current beam production. Finally, we present a simple model of crystal damage due to ion back-bombardment, which agrees qualitatively with the distribution of damage on the substrate surface.
- Publication:
-
Physical Review Accelerators and Beams
- Pub Date:
- December 2011
- DOI:
- 10.1103/PhysRevSTAB.14.120101
- arXiv:
- arXiv:1110.3529
- Bibcode:
- 2011PhRvS..14l0101C
- Keywords:
-
- 29.25.Bx;
- 29.20.Ej;
- 52.59.Sa;
- Electron sources;
- Linear accelerators;
- Space-charge-dominated beams;
- Physics - Accelerator Physics
- E-Print:
- 20 pages, 15 figures