Single ion as a shot-noise-limited magnetic-field-gradient probe
Abstract
It is expected that ion-trap quantum computing can be made scalable through protocols that make use of transport of ion qubits between subregions within the ion trap. In this scenario, any magnetic field inhomogeneity the ion experiences during the transport may lead to dephasing and loss of fidelity. Here we demonstrate how to measure, and compensate for, magnetic field gradients inside a segmented ion trap, by transporting a single ion over variable distances. We attain a relative magnetic field sensitivity of ΔB/B0~5×10-7 over a test distance of 140 μm, which can be extended to the mm range, still with sub-μm resolution. A fast experimental sequence is presented, facilitating its use as a magnetic-field-gradient calibration routine, and it is demonstrated that the main limitation is the quantum shot noise.
- Publication:
-
Physical Review A
- Pub Date:
- June 2011
- DOI:
- 10.1103/PhysRevA.83.062329
- arXiv:
- arXiv:1103.2253
- Bibcode:
- 2011PhRvA..83f2329W
- Keywords:
-
- 03.67.Lx;
- 37.10.Ty;
- 42.50.Dv;
- Quantum computation;
- Ion trapping;
- Nonclassical states of the electromagnetic field including entangled photon states;
- quantum state engineering and measurements;
- Quantum Physics
- E-Print:
- 5 pages, 3 figures