Measurement of the temperature of an ultracold ion source using time-dependent electric fields
Abstract
We report on a measurement of the characteristic temperature of an ultracold rubidium ion source, in which a cloud of laser-cooled atoms is converted to ions by photo-ionization. Extracted ion pulses are focused on a detector with a pulsed-field technique. The resulting experimental spot sizes are compared to particle-tracking simulations, from which an effective source temperature T = (3 ± 2) mK and the corresponding transversal reduced emittance ɛr = 1.4 × 10-8 m rad √eV are determined. Space charge effects that may affect the measurement are also discussed.
- Publication:
-
Journal of Applied Physics
- Pub Date:
- July 2011
- DOI:
- 10.1063/1.3605555
- arXiv:
- arXiv:1011.2369
- Bibcode:
- 2011JAP...110b4501D
- Keywords:
-
- focused ion beam technology;
- ion sources;
- particle beam focusing;
- photoionisation;
- 29.25.Lg;
- 07.77.Ka;
- 29.27.-a;
- Ion sources: polarized;
- Charged-particle beam sources and detectors;
- Beams in particle accelerators;
- Physics - Atomic Physics;
- Physics - Instrumentation and Detectors
- E-Print:
- 8 pages, 11 figures