Abstract
A calorimetric-time-of-flight technique was used for real-time, high-precision measurement of neutron spectra at an angle of 175 o from the initial proton beam direction, which hits a face plane of a cylindrical lead target of 20 cm in diameter and 25 cm thick. A comparison was performed between the neutron spectra predicted by the MARS, RTS&T, MCNP6, and the MCNPX 2.6.0 transport codes and that measured for 200, 400, 600, 800, and 1000 MeV protons. Neutron spectra were measured within the energy range from 0.7 to 250 MeV almost continuously. The transport codes tested here describe with different success the measured spectra, depending on the energy of the detected neutrons and on the incident proton energy, but all the models agree reasonably well with our data.
- Publication:
-
Nuclear Instruments and Methods in Physics Research B
- Pub Date:
- November 2010
- DOI:
- arXiv:
- arXiv:1006.4899
- Bibcode:
- 2010NIMPB.268.3426A
- Keywords:
-
- Nuclear Experiment;
- Nuclear Theory
- E-Print:
- 23 pages, 12 figures, only pdf, submitted to NIM B