Transparency of 0.2% GdCl 3 doped water in a stainless steel test environment
Abstract
The possibility of neutron and neutrino detection using water Cherenkov detectors doped with gadolinium holds the promise of constructing very large high-efficiency detectors with wide-ranging application in basic science and national security. This study addresses a major concern regarding the feasibility of such detectors: the transparency of the doped water to the ultraviolet Cherenkov light. We report on experiments conducted using a 19-m water transparency measuring instrument and associated material test tank. Sensitive measurements of the transparency of water doped with 0.2% GdCl 3 at 337, 400 and 420 nm were made using this instrument. These measurements indicate that the use of GdCl 3 in stainless steel constructed water Cherenkov detectors is problematic.
- Publication:
-
Nuclear Instruments and Methods in Physics Research A
- Pub Date:
- October 2008
- DOI:
- 10.1016/j.nima.2008.06.049
- arXiv:
- arXiv:0805.1499
- Bibcode:
- 2008NIMPA.595..339C
- Keywords:
-
- Physics - Instrumentation and Detectors;
- High Energy Physics - Experiment;
- Nuclear Experiment
- E-Print:
- 17 pages, 11 figures, corrects typos, changes formatting, adds error bars to figure 7