Long-time stable high-temperature superconducting DC-SQUID gradiometers with silicon dioxide passivation for measurements with superconducting flux transformers
Abstract
In applications for high-Tc superconducting DC-SQUIDs such as biomagnetism, nondestructive evaluation and the relaxation of magnetic nanoparticles, it is important to maintain reliable sensor performance over an extended time period. We have designed and produced DC-SQUID gradiometers based on YBa2Cu3O7-x (YBCO) thin films which are inductively coupled to a flux transformer to achieve a higher sensitivity. The gradiometers are protected against ambient atmosphere and humidity by SiO2 and amorphous YBCO layers.
The noise properties of the sensor in flip-chip configuration, especially in unshielded environments, are shown. We present a comparison of Tl2Ba2CaCu2O8+x (TBCCO) thin films on buffered sapphire or LaAlO3 substrates for the flux transformer in shielded and unshielded environments. We reach a low white field gradient noise of 72 fT cm-1 Hz-1 with the TBCCO on LaAlO3 flux transformer. The electric properties of the gradiometers (critical current IC, normal state resistance RN and the transfer function VΦ) were measured over a period of one year and do not show significant signs of degradation.- Publication:
-
Superconductor Science Technology
- Pub Date:
- November 2007
- DOI:
- 10.1088/0953-2048/20/11/S15
- arXiv:
- arXiv:0707.4457
- Bibcode:
- 2007SuScT..20S.380S
- Keywords:
-
- Condensed Matter - Superconductivity
- E-Print:
- 9 pages, 8 figures, ISEC 2007