Development of a 5 MHz frequency difference pre-multiplier for a short term frequency stability bench of the oscillators
Abstract
This paper reports the realization of a 5 MHz frequency difference x10 pre-multiplier, developed in the laboratory to replace an obsolete one. The principle we chose is to synthesize a 45 MHz and a 50 MHz from a reference signal and from the signal to be measured, and to subtract one to the other to generate a 5 MHz, whose precision on the measurement is increased by a factor 10. Obtained Allan variance y() at 1 s is 5.10-14 and output spectral density of phase noise floor is about -160 dBc/Hz at 5 MHz.
- Publication:
-
arXiv e-prints
- Pub Date:
- June 2007
- DOI:
- 10.48550/arXiv.0706.1853
- arXiv:
- arXiv:0706.1853
- Bibcode:
- 2007arXiv0706.1853S
- Keywords:
-
- Physics - Instrumentation and Detectors
- E-Print:
- Proceedings of the IEEE Frequency Control Symposium &