Well spacing of the doublet at the Huangtsuishan geothermal site, Taiwan
Abstract
The issue of thermal breakthrough is often encountered in the extraction of geothermal fluids with reinjection. This study analyzes the minimum safe distance between doublet wells that will maintain thermal productivity under various conditions at the Huangtsuishan geothermal site. A conceptual model is constructed and hypothetical exploitation scenarios are explored. The results show that a distance of 300 m is required to avoid a thermal break in 80 years with 120 tons/hour pumped and 90 % reinjected at the Huangtsuishan Geothermal site. A regression formula was provided as a guideline for the minimum required doublet distance for various pumping rates.
- Publication:
-
Geothermics
- Pub Date:
- January 2021
- DOI:
- 10.1016/j.geothermics.2020.101968
- Bibcode:
- 2021Geoth..8901968C
- Keywords:
-
- Geothermal doublet;
- Thermal breakthrough;
- Cold front propagation